CS14 & CSN14 Series Converter Switches Installation and User Guide (09/09)
2
www GarrettCom com
..
Address buffer age-out time: 300 sec.
Packet buffers memory: 128KB, dynamically shared on all domains
Latency (not including packet time):
100 to 10 Mbps: <5μs 10 to 100Mbps: <15μs
100 to 100Mbps: <4μs 10 to 10Mbps: <13μs
Path Delay Value: 50 BT on all ports
Maximum Ethernet Segment (or Domain) Lengths
10BASE-T (Unshielded twisted pair) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
100BASE-FX, half-duplex: (multi-mode) - 412 m (1350 ft)
100BASE-FX, full-duplex: (multi-mode) - 2.0 km (6,562 ft)
100BASE-FX, half-duplex: (single-mode) - 412 m (1350 ft)
100BASE-FX, full-duplex: (single-mode) - 20.0 km (65,620 ft)
100BASE-FX, full-duplex: (single-mode, long reach) - 40.0 km (131,240 ft)
10BASE-FL, Fiber optic - 2.0 km (6,562 ft)
10BASE-FL, Single-mode Fiber optic - 10.0 km (32,810ft)