6K SNMP Agent supports all (v1/v2c/v3) versions.
Magnum6K25# show snmp
SNMP v3 Configuration Information
=============================
System Name : Magnum6K25
System Location : Fremont, CA
System Contact : [email protected]
Authentication Trap : Disabled
Default Trap Comm. : public
V3 Engine ID : 6K_v3Engine
Magnum6K25# snmpv3
Switch over to SNMPv3 from this point forward
Magnum6K25(snmpv3)## setvar sysname=my_m6k syscontact=admin syslocation=lab
Magnum6K25(snmpv3)# quickcfg
This will enable default VACM.
Do you wish to proceed? [ 'Y' or 'N' ] Y
Quick configuration done, default VACM enabled
Magnum6K25(snmpv3)## engineid string=Magnum6K
Engine ID is set successfully
Magnum6K25(snmpv3)## authtrap enable
Authentication trap status is set successfully
Magnum6K25(snmpv3)## show-authtrap
Authentication Trap Status: Enabled
Magnum6K25(snmpv3)## deftrap community=mysecret
Default trap community is set successfully
Magnum6K25(snmpv3)## show-deftrap
Default Trap Community : public
Magnum6K25(snmpv3)## trap add id=1 type=v1 host=10.21.1.100
Entry is added successfully
M
ax limit of system variables is
15 characters